Wiring Verification: Polarity, Terminals, and Common Receptacle Faults

At startup you confirm devices are wired correctly. Getting polarity and grounding right is a safety issue, not just a formality.

1. Which wire goes where

ConductorTerminalMemory aid
Hot (ungrounded)brass / gold screwbrass = "hot brass"
Neutral (grounded)silver screwsilver = neutral
Ground (EGC)green screwgreen = ground

On the receptacle face, the wider (taller) slot is the neutral; the narrow slot is hot; the round hole is ground. Correct polarity means hot lands on brass and neutral on silver.

2. Common faults (what a 3-light tester finds)

  • Reversed polarity: hot and neutral swapped. Dangerous — normally "neutral" exposed parts (like a lamp's screw shell) become energized.
  • Open ground: the EGC path isn't connected — no fault-clearing path for the device.
  • Open neutral: the return path is broken — the load won't operate, and you can get erratic or "floating" voltage.
  • Bootleg ground: neutral jumpered to the ground terminal to fake a ground — a dangerous, prohibited practice that puts the EGC/enclosure at neutral potential and defeats real grounding.

More Startup, Troubleshooting & Maintenance lessons

Browse the full C-10 curriculum or try the practice test.